Hitte Natural Convection LPHW Trench Heating

From: £335.00 ex VAT

Hitte Natural Convection Trench Heating is ideal for counteracting heat loss and condensation in highly glazed areas. It uses a piped hot water (LPHW) supply to deliver naturally rising heat to the air by means of a heat exchanger, Hot water can be supplied from a conventional hot water boiler, solar energy hot water system or a ground source heat pump. The heat output directly relates to the flow/return temperatures of that source. Internal surfaces are insulated and coated with heat reflective finish to improve the efficiency of the trench.

Select a product from stock below for fast delivery, or contact our Technical Sales Team to explore and select from the vast range of height (depth), width and length configurations available in the full Hitte range, as well as the many choices of grilles, trough materials and finishes.

Outputs in the drop-down menu are based on mean 70 degrees C water temperature, 20 degrees C ambient room temperature.

View full product description
Clear

Enquire about wholesale orders for Hitte Natural Convection LPHW Trench Heating

Send enquiry or call on 01450 372103

Product Description

Trench Heating is now universally found throughout buildings of all type including homes, offices, restaurants, shopping malls, galleries and museums providing discreet heating within entrance halls, reception areas, corridors, living and office spaces and conservatories.

Subtle, it perfectly complements the modern minimalist interior design style and is ideal where space is at a premium. It is often the architect’s heating system of choice when seeking to utilise natural light in the most effective way and incorporating large areas of glazing in new developments, building extensions or refurbishments.

Hitte Natural Convection Trench heating is a highly effective, quiet and discreet heating solution. It is set into the floor, within a trench, and the heat rises, by means of natural convection, through an attractive aluminium grille that sits flush with the floor surface. It can be used either as a primary heating system or a secondary system where it will help increase overall heating system efficiency by counteracting downdraught and condensation in highly glazed areas.

The Hitte Natural Convection Trench Heating units use piped hot water (LPHW) as the heat source. Hot water can be supplied from a conventional hot water boiler, solar energy hot water system or a ground source heat pump. The heat output directly relates to the flow/return temperatures of that source. Internal surfaces are insulated and coated with heat reflective finish to improve the trench’s efficiency.

Key Features

  • 5 standard stock models for fast delivery
  • Standard grille – natural aluminium anodised finish
  • Standard Trough Material – 304L Stainless Steel
  • Multiple knock-out options for pipe connections
  • Cover plates to protect water & electrical connections
  • Adjustable levelling legs
  • Spacers to protect geometry during installation
  • 18mm MDF covers to protect units from construction debris during installations

~Many geometries & configurations available in the full Natural Trench Heating range~

  • ~Choice of grilles-natural, light bronze, dark bronze painted aluminium or oak, ash, beech
  • ~Choice of edgings-natural, light bronze, dark bronze painted aluminium
  • ~Models available for wet environments – 316 Stainless Steel trough
  • ~Models available for external/conditioned air supply
  • ~Dummy units for continuous aesthetics in long runs
  • ~Curved Trench & Mitred corners

~Configure your system using our Product Specification & Costing Tool~

 

Technical Specifications

Natural Convection Trench Heater
Product Codes
(stock models)
Depth/Height
(mm)
Width
(mm)
Length
(mm)
Heat Output
at mean water
temp 70C
(W)
HitteNXX0801752000XNXX801752000249
HitteNXX0803052000XNXX803052000477
HitteNXX1251752000XNXX1251752000462
HitteNXX1253051000XNXX1253051000356
HitteNXX1253052000XNXX1253052000875
The table above relates to our 5 standard stock models. The heat outputs indicated are based on a typical boiler system with mean water temperature of 70C, an ambient room temp of 20C and the fan speed is set at 70%.

~To see full product range download the Natural Trench Brochure above~

 

Natural Convection Trench Heater
Product Codes
(stock models)
Height/Depth
(mm)
Width
(mm)
Length
(mm)
Heat Output
at mean water
temp 45C
(W)
HitteNXX0801752000XNXX801752000113
HitteNXX0803052000XNXX803052000213
HitteNXX1251752000XNXX1251752000199
HitteNXX1253051000XNXX1253051000141
HitteNXX1253052000XNXX1253052000346
The table above relates to our 5 stock models. The heat outputs indicated are based on a lower mean water temperature of 45C where heat source may be a ground source heat pump, the ambient room temperature is 20C and the fan speed is set at 70%.

~To see full product range download the Natural Trench Brochure above~

 

Design & Installation

Trench heating systems can be supplied in a multitude of geometries and with additional features such as ‘dummy’ sections where a continuous aesthetic is desired without additional heat output, with mitred corners, column features and even with curved trench sections. We’d be delighted to help you explore options and design your optimum scheme. Just contact us for assistance and to talk through your ideas.

Our Trench Heaters should be installed by suitably qualified builders and plumbers. The unit should be securely fixed and all water connections installed as per instructions.

 

ACCESSORIES & ALTERNATIVES